99mTc-mebrofenin hepatobiliary scintigraphy and volume metrics before liver preparation: correlations and discrepancies in non-cirrhotic patients - Université de Montpellier Accéder directement au contenu
Article Dans Une Revue Annals of translational medicine Année : 2021

99mTc-mebrofenin hepatobiliary scintigraphy and volume metrics before liver preparation: correlations and discrepancies in non-cirrhotic patients

Résumé

Background: Accurate identification of insufficient future liver remnant (FLR) is required to select patients for liver preparation and limit the risk of post-hepatectomy liver failure (PHLF). The objective of this study was to investigate the correlations and discrepancies between the most-commonly used FLR volume metrics and 99mTc-mebrofenin hepatobiliary scintigraphy (HBS). Methods: In 101 non-cirrhotic patients who underwent HBS before major hepatectomy, we retrospectively analyzed the correlations and discrepancies between FLR function and FLR volume metrics: actual percentage (FLRV%), standardized to body surface area (FLRV%BSA) and weight (FLRV%weight), and FLR to body weight ratio (FLRV-BWR). Results: Among 67 patients with FLR function ≥2.69%/min/m2, PHLF was observed in none and 13 patients according to respectively 50-50 and ISGLS criteria. FLRV%, FLRV%BSA, FLRV%weight and FLRV-BWR significantly correlated with FLR function (P<0.001), with Spearman's correlation coefficients of 0.680, 0.704, 0.698, and 0.711, respectively. No difference was observed between the areas under the curve of FLRV%, FLRV%BSA, FLRV%weight and FLR-BWR (all P=ns). Overall, the percentages of patients misclassified by FLRV%, FLRV%BSA, FLRV%weight (thresholds: 30%) and FLR-BWR (threshold: 0.5) versus FLR function (threshold: 2.69%/min/m2) were 23.8% (95% CI: 15.9-33.3%), 18.8% (95% CI: 11.7-27.8%), 17.8% (95% CI: 11-26.7%), and 31.7% (95% CI: 22.8-41.7%), respectively. FLR volume metrics wrongly classified 1-13.9% of patients with sufficient FLR function (i.e., ≥2.69%/min/m2), and 9.9-30.7% of patients with insufficient FLR function. FLRV-BWR was the most and the least reliable measure to identify patients with sufficient and insufficient FLR function, respectively. Conclusions: Despite significant correlations, the discrepancy rates between FLR volume and function metrics speaks in favor of implementing 99mTc-mebrofenin HBS in the work-up before liver preparation.
Fichier principal
Vignette du fichier
atm-09-09-795.pdf (832.64 Ko) Télécharger le fichier
Origine : Fichiers éditeurs autorisés sur une archive ouverte

Dates et versions

hal-03647029 , version 1 (20-04-2022)

Licence

Paternité - Pas d'utilisation commerciale - Pas de modification

Identifiants

Citer

Boris Guiu, Emmanuel Deshayes, Fabrizio Panaro, Florian Sanglier, Caterina Cusumano, et al.. 99mTc-mebrofenin hepatobiliary scintigraphy and volume metrics before liver preparation: correlations and discrepancies in non-cirrhotic patients. Annals of translational medicine, 2021, 9 (9), pp.795-795. ⟨10.21037/atm-20-7372⟩. ⟨hal-03647029⟩
37 Consultations
41 Téléchargements

Altmetric

Partager