Imaged-guided liver stereotactic body radiotherapy using VMAT and real-time adaptive tumor gating. Concerns about technique and preliminary clinical results

Abstract : BACKGROUND: Motion management is a major challenge in abdominal SBRT. We present our study of SBRT for liver tumors using intrafraction motion review (IMR) allowing simultaneous KV information and MV delivery to synchronize the beam during gated RapidArc treatment. MATERIALS AND METHODS: Between May 2012 and March 2015, 41 patients were treated by liver SBRT using gated RapidArc technique in a Varian Novalis Truebeam STx linear accelerator. PTV was created by expanding 5 mm from the ITV. Dose prescription ranged from 40 to 50 Gy in 5-10 fractions. The prescribed dose and fractionation were chosen depending on hepatic function and dosimetric results. Thirty-four patients with a minimal follow-up of six months were analyzed for local control and toxicity. Accuracy for tumor repositioning was evaluated for the first ten patients. RESULTS: With a median follow-up of 13 months, the treatment was well tolerated and no patient presented RILD, perforation or gastrointestinal bleeding. Acute toxicity was found in 3 patients with G1 abdominal pain, 2 with G1 nausea, 10 with G1 asthenia and 1 with G2 asthenia. 6 patients presented asymptomatic transitory perturbation of liver enzymes. In-field local control was 90.3% with 7 complete responses, 14 partial responses and 7 stabilisations. 3 patients evolved "in field". 12 patients had an intrahepatic progression "out of field". Mean intrafraction deviation of fiducials in the craneo-caudal direction was 0.91 mm (0-6 mm). CONCLUSION: The clinical tolerance and oncological outcomes were favorable when using image-guided liver SBRT with real-time adaptive tumor gating.
Type de document :
Article dans une revue
Liste complète des métadonnées

https://hal.umontpellier.fr/hal-02316275
Contributeur : Nathalie Salvy-Cordoba <>
Soumis le : mardi 15 octobre 2019 - 11:04:11
Dernière modification le : jeudi 17 octobre 2019 - 17:05:44

Lien texte intégral

Identifiants

Citation

Carmen Llacer-Moscardo, Olivier Riou, David Azria, Ludovic Bedos, Norbert Ailleres, et al.. Imaged-guided liver stereotactic body radiotherapy using VMAT and real-time adaptive tumor gating. Concerns about technique and preliminary clinical results. Reports of Practical Oncology & Radiotherapy, Elsevier, 2017, 22 (2), pp.141-149. ⟨10.1016/j.rpor.2016.06.004⟩. ⟨hal-02316275⟩

Partager

Métriques

Consultations de la notice

12