Treatment of Intracranial Aneurysms with Self-Expandable Braided Stents: A Systematic Review and Meta-Analysis - Université de Montpellier
Article Dans Une Revue American Journal of Neuroradiology Année : 2018

Treatment of Intracranial Aneurysms with Self-Expandable Braided Stents: A Systematic Review and Meta-Analysis

Résumé

BACKGROUND: The safety and efficacy of treatment with self-expandable braided stents (LEO and LVIS) required further investigation. PURPOSE: Our aim was to analyze the outcomes after treatment with braided stents. DATA SOURCES: A systematic search of 3 databases was performed for studies published from 2006 to 2017. STUDY SELECTION: According to Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines, we included studies reporting patients treated with LEO or LVIS stents. DATA ANALYSIS: Random-effects meta-analysis was used to pool the following: aneurysm occlusion rate, complications, and neurologic outcomes. DATA SYNTHESIS: Thirty-five studies evaluating 1426 patients treated with braided stents were included in this meta-analysis. Successful stent delivery and complete aneurysm occlusion were 97% (1041/1095; 95% CI, 95%-98%) (I2 = 44%) and 88.3% (1097/1256; 95% CI, 85%-91%) (I2 = 72%), respectively. Overall, treatment-related complications were 7.4% (107/1317; 95% CI, 5%-9%) (I2 = 44%). Ischemic/thromboembolic events (48/1324 = 2.4%; 95% CI, 1.5%-3.4%) (I2 = 27%) and in-stent thrombosis (35/1324 = 1.5%; 95% CI, 0.6%-1.7%) (I2 = 0%) were the most common complications. Treatment-related morbidity was 1.5% (30/1324; 95% CI, 0.9%-2%) and was comparable between the LEO and LVIS groups. Complication rates between the anterior (29/322 = 8.8%; 95% CI, 3.4%-12%) (I2 = 41%) versus posterior circulation (10/84 = 10.5%; 95% CI, 4%-16%) (I2 = 0%) and distal (30/303 = 8%; 95% CI, 4.5%-12%) (I2 = 48%) versus proximal aneurysms (14/153 = 9%; 95% CI, 3%-13%) (I2 = 46%) were comparable (P > .05). LIMITATIONS: Limitations were selection and publication biases. CONCLUSIONS: In this analysis, treatment with the LEO and LVIS stents was relatively safe and effective. The most common complications were periprocedural thromboembolisms and in-stent thrombosis. The rate of complications was comparable among anterior and posterior circulation aneurysms, as well as for proximal and distally located lesions.

Dates et versions

hal-02313557 , version 1 (11-10-2019)

Identifiants

Citer

F. Cagnazzo, M. Cappucci, P.-H. Lefevre, C. Dargazanli, G. Gascou, et al.. Treatment of Intracranial Aneurysms with Self-Expandable Braided Stents: A Systematic Review and Meta-Analysis. American Journal of Neuroradiology, 2018, 39 (11), pp.2064-2069. ⟨10.3174/ajnr.A5804⟩. ⟨hal-02313557⟩
41 Consultations
0 Téléchargements

Altmetric

Partager

More