Heparin-free renal replacement therapy for chronic hemodialyzed patients at high risk for bleeding: a comparison of on-line predilution hemodiafiltration with conventional hemodialysis
Résumé
In chronic hemodialysis patients with high risk of bleeding, optimal anticoagulation of the extracorporeal circuit is challenging. Heparin-free hemodialysis (HD) with heparin-coated AN69ST dialyzer is now considered as a good option and recommended by experts. Predilutional hemodiafiltration (HDF) may represent also a feasible alternative but has been poorly investigated. In this study, our aim was to evaluate the performance of on-line automated predilution heparin-free HDF as compared to conventional heparin-free HD with a heparin-coated membrane.