Accéder directement au contenu Accéder directement à la navigation
Article dans une revue

Total elbow arthroplasty: Influence of implant positioning on functional outcomes

Abstract : BACKGROUND: Restoring the axis of rotation is often considered crucial to achieving good functional outcomes of total elbow arthroplasty. The objective of this work was to evaluate whether variations in implant positioning correlated with clinical outcomes. HYPOTHESIS: Clinical outcomes are dictated by the quality of implant positioning. MATERIAL AND METHODS: A retrospective review was conducted of data from 25 patients (26 elbows). Function was assessed using a pain score, the Disabilities of the Arm, Shoulder, and Hand (DASH) Score, and the Mayo Elbow Performance Score (MEPS). The patients also underwent a clinical evaluation for measurements of motion range and flexion/extension strength. Position of the humeral and ulnar implants was assessed by computed tomography with reconstruction using OsiriX software. Indices reflecting anterior offset, lateral offset, valgus, height, and rotation were computed by subtracting the ulnar value of each of these variables from the corresponding humeral value. These indices provided a quantitative assessment of whether position errors for the two components had additive effects or, on the contrary, counterbalanced each other. Elbows with prosthetic loosening or extensive epiphyseal destruction were excluded. RESULTS: Of the 26 elbows, 5 were excluded. In the remaining 21 elbows, the discrepancy between the humeral and ulnar lateral offsets was significantly associated with pain intensity (P ≤ 0.05) and the MEPS (P ≤ 0.05). Anterior position of the ulna relative to the humerus was associated with decreased extension strength (P ≤ 0.05) and worse results for all functional parameters (P ≤ 0.05). DISCUSSION: In the absence of loosening, positioning errors seem to adversely affect functional outcomes, probably by placing inappropriate stress on the soft tissues.
Liste complète des métadonnées

https://hal.umontpellier.fr/hal-01949647
Contributeur : Cécile Nowak <>
Soumis le : lundi 10 décembre 2018 - 11:50:23
Dernière modification le : vendredi 15 mai 2020 - 12:22:06

Lien texte intégral

Identifiants

Collections

Citation

Hubert Lenoir, Jean-Paul Micallef, I. Djerbi, Thomas Waitzenegger, Cyril Lazerges, et al.. Total elbow arthroplasty: Influence of implant positioning on functional outcomes. Orthopaedics and Traumatology - Surgery and Research, Elsevier, 2015, 101 (6), pp.721-727. ⟨10.1016/j.otsr.2015.07.008⟩. ⟨hal-01949647⟩

Partager

Métriques

Consultations de la notice

57