Collagen plug-based vascular closure devices do not decrease vascular and bleeding complications occurring after balloon aortic valvuloplasty - Université de Montpellier
Article Dans Une Revue Archives of cardiovascular diseases Année : 2015

Collagen plug-based vascular closure devices do not decrease vascular and bleeding complications occurring after balloon aortic valvuloplasty

Résumé

BACKGROUND: The benefits of vascular closure devices (VCDs) in the prevention of vascular complications after femoral intervention remain controversial. AIM: To evaluate the efficiency of collagen plug-based VCDs in the prevention of femoral access complications after balloon aortic valvuloplasty. METHODS: We conducted a prospective analysis of consecutive patients who underwent balloon aortic valvuloplasty by femoral retrograde technique in our centre between 2009 and 2012. Group 1 included 75 patients in whom femoral puncture haemostasis was obtained with the use of an 8F collagen plug-based VCD (Angio-Seal™; Saint-Jude Medical, Inc.); group 2 included 105 patients who had manual or mechanical groin compression (FemoStop™; RADI Medical Systems, Inc.). We did not use heparin during the procedure. We collected data on major in-hospital adverse events, major bleeding (Bleeding Academic Research Consortium classification≥3) and vascular access complications. RESULTS: We included 180 patients with severe and symptomatic aortic stenosis. Indications for valvuloplasty were mainly bridge to transcatheter aortic valve implantation or palliative therapy (72%). The groups were similar in terms of median age, lower limb artery disease and body mass index. Vascular and bleeding complications occurred in 11.1% of patients and were not decreased with the use of VCDs (relative risk 2.60, 95% confidence interval 1.10-3.09; P=0.05). These findings were consistent across all prespecified subgroups. Duration of hospital stay was not reduced by VCDs. CONCLUSIONS: Based on the results of this study, performed with small-size sheaths and without heparin, collagen plug-based VCDs increase femoral access complications following aortic valvuloplasty. Systematic use of VCDs in elderly patients, with probable advanced limb atherosclerosis, is questionable.

Dates et versions

hal-01773672 , version 1 (23-04-2018)

Identifiants

Citer

Florence Leclercq, Delphine Delseny, Richard Gervasoni, Benoit Lattuca, François Roubille, et al.. Collagen plug-based vascular closure devices do not decrease vascular and bleeding complications occurring after balloon aortic valvuloplasty. Archives of cardiovascular diseases, 2015, 108 (4), pp.250 - 257. ⟨10.1016/j.acvd.2014.11.005⟩. ⟨hal-01773672⟩
84 Consultations
0 Téléchargements

Altmetric

Partager

More