M. Y. Rady, Bench-to-bedside review: Resuscitation in the emergency department, Crit Care, vol.9, issue.2, pp.170-176, 2005.

E. Burri, M. Potocki, B. Drexler, P. Schuetz, A. Mebazaa et al., Value of arterial blood gas analysis in patients with acute dyspnea: an observational study, Crit Care, vol.15, issue.3, p.145, 2011.

X. Bobbia, R. G. Grandpierre, P. G. Claret, A. Moreau, S. Pommet et al., Ultrasound guidance for radial arterial puncture: a randomized controlled trial, Am J Emerg Med, vol.31, issue.5, pp.810-815, 2013.

J. A. Silversides and N. D. Ferguson, Clinical review: Acute respiratory distress syndrome-clinical ventilator management and adjunct therapy, Crit Care, vol.17, issue.2, p.225, 2013.
DOI : 10.1186/cc11867

URL : https://ccforum.biomedcentral.com/track/pdf/10.1186/cc11867

R. D. Restrepo, K. R. Hirst, L. Wittnebel, and R. Wettstein, AARC clinical practice guideline: transcutaneous monitoring of carbon dioxide and oxygen: 2012, Respir Care, vol.57, issue.11, pp.1955-62, 2012.
DOI : 10.4187/respcare.02011

L. Brochard, G. S. Martin, L. Blanch, P. Pelosi, F. J. Belda et al., Clinical review: Respiratory monitoring in the ICU-a consensus of 16, Crit Care, vol.16, issue.2, p.219, 2012.

F. Monaco, B. G. Nickerson, and J. C. Mcquitty, Continuous transcutaneous oxygen and carbon dioxide monitoring in the pediatric ICU, Crit Care Med, vol.10, issue.11, pp.765-771, 1982.

O. Connor, T. A. Grueber, and R. , Transcutaneous measurement of carbon dioxide tension during long-distance transport of neonates receiving mechanical ventilation, J Perinatol, vol.18, issue.3, pp.189-92, 1998.

K. Bendjelid, N. Schütz, M. Stotz, I. Gerard, P. M. Suter et al., Transcutaneous PCO2 monitoring in critically ill adults: clinical evaluation of a new sensor, Crit Care Med, vol.33, issue.10, pp.2203-2209, 2005.

S. Delerme, V. Montout, H. Goulet, A. Arhan, L. Saché et al., Concordance between transcutaneous and arterial measurements of carbon dioxide in an ED, Am J Emerg Med, vol.30, issue.9, pp.1872-1878, 2012.

P. E. Gancel, E. Roupie, L. Guittet, S. Laplume, and N. Terzi, Accuracy of a transcutaneous carbon dioxide pressure monitoring device in emergency room patients with acute respiratory failure, Intensive Care Med, vol.37, issue.2, pp.348-51, 2011.

J. W. Severinghaus, P. Astrup, and J. F. Murray, Blood gas analysis and critical care medicine, Am J Respir Crit Care Med, vol.157, issue.4, pp.114-136, 1998.

J. A. Kellum, Determinants of blood pH in health and disease, Crit Care, vol.4, issue.1, pp.6-14, 2000.

L. T. Heuss, P. N. Chhajed, P. Schnieper, T. Hirt, and C. Beglinger, Combined pulse oximetry/cutaneous carbon dioxide tension monitoring during colonoscopies: pilot study with a smart ear clip, Digestion, vol.70, issue.3, pp.152-160, 2004.

J. H. Storre, B. Steurer, H. J. Kabitz, M. Dreher, and W. Windisch, Transcutaneous PCO2 monitoring during initiation of noninvasive ventilation, Chest, vol.132, issue.6, pp.1810-1816, 2007.

J. Mcvicar and R. Eager, Validation study of a transcutaneous carbon dioxide monitor in patients in the emergency department, Emerg Med J, vol.26, issue.5, pp.344-350, 2009.

M. Cox, R. Kemp, S. Anwar, V. Athey, T. Aung et al., Non-invasive monitoring of CO2 levels in patients using NIV for AECOPD, Thorax, vol.61, issue.4, pp.363-367, 2006.

P. A. Mclellan, R. S. Goldstein, V. Ramcharan, and A. S. Rebuck, Transcutaneous carbon dioxide monitoring, Am Rev Respir Dis, vol.124, issue.2, pp.199-201, 1981.

J. D. Tobias, Transcutaneous carbon dioxide monitoring in infants and children, Paediatr Anaesth, vol.19, issue.5, pp.434-478, 2009.

H. T. Versmold, O. Linderkamp, M. Holzmann, I. Strohhacker, and K. Riegel, Transcutaneous monitoring of PO2 in newborn infants: where are the limits? Influence of blood pressure, blood volume, blood flow, viscosity, and acid base state, Birth Defects Orig Artic Ser, vol.15, issue.4, pp.285-94, 1979.

V. Rosner, B. Hannhart, F. Chabot, and J. M. Polu, Validity of transcutaneous oxygen/carbon dioxide pressure measurement in the monitoring of mechanical ventilation in stable chronic respiratory failure, Eur Respir J, vol.13, issue.5, pp.1044-1051, 1999.

J. P. Janssens, C. Howarth-frey, J. C. Chevrolet, B. Abajo, and T. Rochat, Transcutaneous PCO2 to monitor noninvasive mechanical ventilation in adults: assessment of a new transcutaneous PCO2 device, Chest, vol.113, issue.3, pp.768-73, 1998.

C. J. Lang, Apnea testing guided by continuous transcutaneous monitoring of partial pressure of carbon dioxide, Crit Care Med, vol.26, issue.5, pp.868-72, 1998.

M. Maniscalco, A. Zedda, S. Faraone, P. Carratù, and M. Sofia, Evaluation of a transcutaneous carbon dioxide monitor in severe obesity, Intensive Care Med, vol.34, issue.7, pp.1340-1344, 2008.

A. Cuvelier, B. Grigoriu, L. C. Molano, and J. F. Muir, Limitations of transcutaneous carbon dioxide measurements for assessing long-term mechanical ventilation, Chest, vol.127, issue.5, pp.1744-1752, 2005.

P. Rodriguez, F. Lellouche, J. Aboab, C. B. Buisson, and L. Brochard, Transcutaneous arterial carbon dioxide pressure monitoring in critically ill adult patients, Intensive Care Med, vol.32, issue.2, pp.309-321, 2006.

S. Belenkiy, K. M. Ivey, A. I. Batchinsky, T. Langer, C. Necsoiu et al., Noninvasive carbon dioxide monitoring in a porcine model of acute lung injury due to smoke inhalation and burns, Shock, vol.39, issue.6, pp.495-500, 2013.

W. J. Randerath, S. Stieglitz, W. Galetke, N. Anduleit, M. Treml et al., Evaluation of a system for transcutaneous long-term capnometry, Respiration, vol.80, issue.2, pp.139-184, 2010.