The liquid metal embrittlement of a reactive system at room temperature: α-brasses in contact with the liquid eutectic Ga-In - Laboratoire de mécanique et technologie
Article Dans Une Revue Engineering Failure Analysis Année : 2024

The liquid metal embrittlement of a reactive system at room temperature: α-brasses in contact with the liquid eutectic Ga-In

Résumé

We studied the liquid metal embrittlement (LME) at room temperature of α-brasses by the liquid eutectic Ga-In (EGaIn). The EGaIn partially wets the α-brasses and forms the CuGa2 intermetallic. 3-point bending tests, Finite Element Analysis, and in situ testing were conducted. When LME occurs, there is a ductile fracture followed by an intergranular brittle fracture that propagates through the zones with the highest plastic strain. The LME sensitivity increases with higher strain rates, higher Zn content, and higher work hardening rates, suggesting a significant role of dislocation mobility in LME and a lack of influence from the CuGa2 intermetallic.
Fichier principal
Vignette du fichier
1-s2.0-S1350630724007404-main.pdf (10.43 Mo) Télécharger le fichier
Origine Publication financée par une institution

Dates et versions

hal-04672585 , version 1 (19-08-2024)

Identifiants

Citer

Marco Ezequiel, Ingrid Proriol Serre, Thierry Auger, Eva Héripré, Zehoua Hadjem-Hamouche, et al.. The liquid metal embrittlement of a reactive system at room temperature: α-brasses in contact with the liquid eutectic Ga-In. Engineering Failure Analysis, 2024, 164, pp.108694. ⟨10.1016/j.engfailanal.2024.108694⟩. ⟨hal-04672585⟩
338 Consultations
31 Téléchargements

Altmetric

Partager

More